        中華工控網工控產品 → KW8M環保型功率表
        產品名稱: KW8M環保型功率表
        型 號: KW8M
        價 格:
        品 牌:
         
        收藏此產品     查看收藏

        Lineup with new energy saving and environmentally friendly features!

        Features (AKW8111/AKW8111H)

        1.Direct measurement of 400 V power loads

        2.Three-phase, four-wire system compatibility

        3.Improved measurement function

        • Instantaneous electrical power
        • Integrated electrical power
        • Each phase voltage and current
        • Frequency
        • Power factor

        4.Simultaneous power and pulse measurement

        5.Supports Networking

        • RS485
        • Modbus Protocol
        • MEWTOCOL
        * Modbus is a communication protocol developed for PLCs by Modicon Inc.

        Features (AKW8111H ONLY)

        1.Includes all the features of AKW8111.

        2.Built-in memory

        Log data can be saved to memory of main unit.

        3.Built-in battery (for memory backup)

        Protects log data and time

        4.Optional functions (3 items) added

        • Each integrated electric power by month, day and hour
        • Arbitrary integrated active electrical power
        • Calendar timer function

        4.Simultaneous power and pulse measurement

        5.Supports Networking

        • RS485
        • Modbus Protocol
        • MEWTOCOL
        * Modbus is a communication protocol developed for PLCs by Modicon Inc.
        Main unit
        Phase and wire system Operating power
        supply
        Measured
        voltage input
        Measured
        current input
        Current transformer Terminal type Log function Model No.
        Single-phase two-wire system
        Single-phase three-wire system
        Three-phase three-wire system
        Three-phase four-wire system
        100 to 240 V AC,
        50/60 Hz
        400 V AC
        100/200 V AC

        5 A,
        100 A,
        250 A,
        400 A

        Dedicated CT type
        [5 A, 50 A (common)/
        100 A/250 A/400 A]
        Screw terminal
        (M3 “+” screw)
        Not available AKW8111
        Available AKW8111H
        Dedicated current transformer (CT)
        Rated primary current Part No.
        5A/50A AKW4801
        100A AKW4802
        250A AKW4803
        400A AKW4804
        Options
        Product name Model No.
        Terminal cover AKT8801
        Battery AFC8801

        Measurement items

        Item Unit Data range (Display range)
        Integrated
        electric power
        Active power kWh 0.00 to 9999999.9
        Reactive power kvarh 0.00 to 9999999.9
        Apparent power kVAh 0.00 to 9999999.9
        Instantaneous
        electric power
        Active power kW 0.00 to 999999.99
        Reactive power kvar

        –99999.99 to 0.00 to 999999.99

        Apparent power kVA 0.00 to 999999.99
        Current CT1 current A 0.0 to 6000
        CT2 current A 0.0 to 6000
        CT3 current A 0.0 to 6000
        Voltage Voltage between P1 and P0 V 0.0 to 9999
        Voltage between P2 and P0 V 0.0 to 9999
        Voltage between P3 and P0 V 0.0 to 9999
        Electricity charge* - 0.00 to 99999999
        Power factor Display 0.00 to 1.00 (Distiguishes if ahead (LEAD) or behind (LAG).)
        Communication –1.00 to 0.00 to 1.00 (Within range of phase angle θ = –90 to 0 to +90°)
        Frequency Hz 47.5 to 63.0
        Hour meter ON time Time 0.0 to 99999.9
        OFF time
        Pulse counter - 0 to 99999999
        * Eco-POWER METER is designed chiefly for managing energy saving.
        It is not intended to be used for billing.

        Main unit

        Item Specifications
        Rated operating voltage 100 to 240V AC
        Rated frequency 50/60Hz common
        Rated power consumption 8VA
        Inrush current 30 A or less (200 VAC at 25°C)
        Allowable operating voltage range 10ms
        Allowable momentary power-off time –10 to +50°C (–25°C to +70°C at storage)
        Ambient temperature 30 to 85%RH (at 20°C non-condensing)
        Breakdown voltage (initial) Between the isolated circuits: 2000V for 1min
        Note: Cut-off current: 10mA
        However protective varistor excluded.
        • Outer edge (case) ⇔ All terminals
        • Insulated circuit
        • GND ⇔ All other terminals
        • Operating power supply terminals ⇔ Analog input terminals*1
        • Operating power supply terminals ⇔ Pulse input terminal
        • RS485 ⇔ All other terminals
        • Pulse output terminals ⇔ All other terminals
        Insulation resistance (initial) Between the isolated circuits:100MΩ or more
        (measured at 500V DC)
        Vibration resistance 10 to 55Hz (1cycle/min) single amplitude: 0.375mm (1h on 3 axes)
        Shock resistance Min. 294m/s2 (5 times on 3 axes)
        Display method 8-digit, 7-segment LED
        Power failure memory method EEP-ROM (more than 100,000 overwrite)
        Size 48 × 96 × 98.5 mm
        Weight*2 AKW8111: approx.235g AKW8111H: approx.250g
        *1 Analog input terminals: No.11 to 20 / Pulse input terminal: No.4 and 5
        *2 Without mounting bracket

        Input specifications

        Item Specifications
        Measured
        input voltage
        Rating

        Single-phase two-wire: 0 to 440V AC (Line voltage)
        Single-phase three-wire: 0 to 220V AC (Phase voltage)
        Three-phase three-wire: 0 to 440V AC (Line voltage)
        Three-phase four-wire: 0 to 254V AC (Phase voltage)

        Allowance 85% to 120% of rated input voltage
        Allowable measurement
        voltage
        Single-phase two-wire: 0 to 528V AC (Line voltage)
        Single-phase three-wire: 0 to 264V AC (Phase voltage)
        Three-phase three-wire: 0 to 528V AC (Line voltage)
        Three-phase four-wire: 0 to 300V AC (Phase voltage)
        VT ratio

        1.00 to 99.99 (Set with setting mode)
        *Voltage transformer (VT) is required when you measure a load with voltage over 440V system. (Secondary side: 110V)

        Measured
        input current
        Primary side rating

        • 5A/50A/100A/250A/400A (In case using dedicated CT.) (Select with setting mode)
        • 1 to 4000A (Set with setting mode)
        *Use a commercial CT with secondary side current of 5A when measure 400A or more.
        *Accuracy coverage: 10 to 100% of rated current of CT

        Special
        functions
        Cut-off current 1.0 to 50.0%F.S. (Select with setting mode)
        Current threshold for hour
        meter
        1.0 to 100.0%F.S. (Select with setting mode)
        Accuracy
        (without
        error in CT
        and VT)

        Instantaneous electric power
        (active/reactive/apparent)
        Integrated electric power
        (active/reactive/apparent)
        Voltage
        Current
        Electricity charge

        ±2.5% F.S. ±1digit (at 20°C, rated input, rated frequency, power-factor 1)
        *Accuracy coverage: 10 to 100% of rated current of CT
        Hour meter ±0.01%±1digit (at 20°C) (In case power on start or current energizing: ±0.01%+1s±1 digit)
        Temperature characteristics ±1.5% F.S. /10°C ±1digit (Range of –10 to 50°C for rated input power-factor 1)
        Frequency characteristics ±1.5% F.S.±1 digit (Frequency change±5% based on rated frequency, for rated input power-factor 1)

        Pulse input specifications

        Item Specifications
        Input mode Addition (Fixed)
        Max. counting speed 2kHz/30Hz (Select with setting mode)
        Pulse input Min. input signal width:
        0.25ms (When 2kHz selected)/
        16.7ms (When 30Hz selected)
        ON:OFF ratio = 1 : 1
        Input signal

        Contact/No contact (open collector)
        Impedance when shorted: 1kΩ
        Residual voltage when shorted: Max. 2V
        Impedance when open: 100kΩ

        Output mode HOLD (Over count)
        Number of digit 8-digit (0 to 99999999)

        Output specifications

        Item Specifications
        Number of output point 1 point
        Insulation method Optical coupler
        Output type Open collector
        Output capacity

        100mA 30V DC

        Pulse width Approx. 100ms
        ON state voltage drop 1.5V or less
        OFF state leakage current 100μA or less
        Pulse output unit 0.001/0.01/0.1/1/10/100kWh/
        Alarm(AL-P)/Counter(Cnt)
        (Selectable with setting mode)
        * We recommend the setting of minimum unit for pulse output for measurement shown as below.
        Output pulse: 4 pulse or less per 1sec.

        Communication Specifications

        Item Specifications
        Interface Conforming to RS485
        Protocol MEWTOCOL/MODBUS(RTU)
        Isolation status Isolated with the internal circuit
        Number of connected units 99 (max.)*2 *3
        Transmission distance 1200m (max.)*1
        Transmission speed 19200/9600/4800/2400bps (selectable with setting mode)
        Log function
        Memory of main unit
        Data length 8bit/7bit (selectable with setting mode)*4
        Parity Not available / Odd number / Even number (selectable with setting mode)
        Stop bit 1bit (fixed)
        Communication method Half-duplex
        Synchronous system

        Synchronous communication method

        Ending resistance Approx. 120Ω (built-in)

        Factory settings

        Protocol Station no. Transmission speed
        (Baud rate)
        Data length Parity Stop bit
        MEWTOCOL 1 19200 bps 8-bit Odd number 1 bit (fixed)
        *1 Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, transmission speed may be different according to using transmission line.
        *2 For RS485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co., Ltd.).
        *3 When using SI-35,SI-35USB or PLC from Panasonic Electric Works Co., Ltd. (which can be connected up to 99 units), up to 99 Eco-POWER METER can be connected.
        In case using this system with the other devices, up to 31 Eco-POWER METER can be connected.
        *4 With MODBUS(RTU) protocol, it works only with 8bit.

        Optional specifications (AKW8111H only)

        Item Specifications
        Log function
        Memory of main unit
        Automatic
        logging
        Save cycle 60 min.
        Save data Integrated active power, Integrated reactive power, Integrated apparent power
        Save data amount Max. 2232 records *3 months
        Display Integrated electric power by month, Integrated electric power by day, Integrated electric power by hour
        Selected
        logging*1
        Save cycle 1, 5, 10, 15, 30, 60 min.
        Save data

        Integrated active power, Integrated reactive power, Integrated apparent power, Instantaneous voltage,
        Instantaneous current, Pulse count value

        Save data amount Max. 2160 records *1.5 days (when save frequency is 1 min.)
        Calendar timer function Time accuracy monthly accuracy: 240 sec. (at –10°C)
        monthly accuracy: 70 sec. (at 25°C)
        monthly accuracy: 240 sec. (at 50°C)
        Arbitrary integrated active power

        Integrated active power in arbitrary time Display range: 0.00 to 9999999.9 kWh

        Content of battery backup Time measurement and log data retained
        Battery life*2 *3 About 5 years (at ambient temperature 25°C)
        *1

        Another software is required to check selectable log data saved in the built-in memory. The recommended software, KW Monitor, is available for download from here.

        *2 When battery power is reduced, “E” is blinking. Please change the battery according to the battery replacement procedure.
        *3 Battery life will shorten if this product is used in high temperature environments.

        Dedicated Current Transformer (CT) Specifications

        Model number AKW4801 AKW4802 AKW4803 AKW4804
        Primary side rated current 5A/50A 100A 250A 400A
        Rated secondary side current 1.67mA/16.7mA 33.3mA 125mA 200mA
        Winding (Turn) 3000 3000 2000 2000
        Ratio error ±1.0%F.S.
        Hole Dia (mm) 10 dia. 16 dia. 24 dia. 36 dia.
        Breakdown voltage (initial) 1000V AC/1min
        (Between through hole and
        output lead wire)
        2000V AC/1min
        (Between through hole and output lead wire)
        Insulation resistance (initial) Min. 100MΩ (at DC500V) (Between through hole and output lead wire)
        Functional vibration resistance 10 to 55Hz (1cycle/minute) single amplitude of 0.15mm (10 min. on X, Y and Z axes)
        Destructive vibration resistance 10 to 55Hz (1cycle/ minute) single amplitude of 0.375mm (1 hrs. on X, Y and Z axes)
        Functional shock resistance Min. 98m/s2 (4 times on X, Y and Z axes)
        Destructive shock resistance Min. 294m/s2 (5 times on X, Y and Z axes)
        Output protection level ±7.5V with clamp element ±3.0V with clamp element
        Permissible clamping frequency Approx. 100 times
        Ambient temperature –10 to +50°C (without frost and non-condensing)
        Storage temperature –20 to +60°C (without frost and non-condensing)
        Ambient humidity 35 to 85%RH (at 20°C non-condensing)
        Weight Approx. 50g
        (Trunk cable included)
        Approx. 80g
        (Trunk cable included)
        Approx. 200g
        (Trunk cable included)
        Approx. 300g
        (Trunk cable included)
        * Dedicated current transformers (CT), AKW4801, AKW4802, AKW4803, AKW4804, are dedicated for low voltage under 440V system. They can not be used for high voltage circuit. In case measuring high voltage circuit, make a 2-step construction by combination of a commercial CT of secondary side current 5A for high voltage and the dedicated CT for 5A (AKW4801).
      • Unit
      • mm
        inch
        External Dimensions
        • akw8111e.dxfDownload
        Terminal arrangement

        Software Download

        Tool/Software

        Download Software Size Update
        KW Monitor Ver.1.41 9.7MB November 1, 2008
      •  


        公司簡介
        產品目錄
        供應信息

        公司名稱: 深圳市森林森機電設備有限公司
        電 話: 0755 83994350 / 何躍民
        手機:
        地 址: 深圳市羅湖區寶安南路北京大廈1002室
        郵 編: 518013
        主 頁: www.senlinsen.com

        該廠商相關產品:
      • FP-X可編程控制器
      •  
      • 松下FP2可編程控制器
      •  
      • 可編程控制器 FP-X
      •  
      • 松下FP0系列可編程控制器
      •  
      • 松下FPΣ系列可編程控制器
      •  
      • 松下FP-e可編程控制器
      •  
      • 可編程控制器FP0系列
      •  
      • 松下GT01可編程智能操作面板
      •  
      • TH8DC計時器
      •  
      • KW4M環保型功率表
      •  
        更多產品...
          關于我們 | 聯系我們 | 廣告服務 | 本站動態 | 友情鏈接 | 法律聲明 | 非法和不良信息舉報  
        工控網客服熱線:0755-86369299
        版權所有 工控網 Copyright@ Gkong.com, All Rights Reserved

        主站蜘蛛池模板: 国产精品自拍视频第一页| 国模吧双双大尺度炮交gogo| 亚洲一区二区三区在线播放无码| 疯狂做受XXXX高潮国产| 欧美性一区| a在线观看视频在线播放| 精品人妻少妇一区二区三区在线| 欧美日韩视频综合一区无弹窗| 午夜成人无码免费看网站| 人妻丰满熟妇av无码区乱| 性欧美vr高清极品| 亚洲综合国产一区二区三区| 国产肥妇一区二区熟女精品| 亚洲AV无码久久精品日韩| 久久国产精品老女人| 欧美牲交A欧美在线| 夜色福利站www国产在线视频| 国产成熟女人性满足视频| 欧美性猛交xxx嘿人猛交| 成人国产精品一区二区不卡| 无码中文字幕热热久久| 九九热精品在线观看| 国产国语对白露脸正在播放| 亚洲情综合五月天| 国厂精品114福利电影免费| 色欲天天天综合网| 羞羞影院午夜男女爽爽免费视频| 久久久噜噜噜久久中文福利| 麻豆一区二区三区香蕉视频| 成人精品一区二区三区不卡免费看 | 国产乱码精品一区二区三区中文| 日本深夜福利在线观看| 亚洲欧美在线观看一区二区| 久久激情影院| 精品熟女少妇av免费观看| 天天综合网网欲色| 亚洲经典一区二区三区四区| 农村老熟妇乱子伦视频| 国产目拍亚洲精品区一区| 日韩中文字幕精品人妻| 国产精品黑色丝袜在线观看|